Inverter Relay Clicking On and Off

UPS ProblemsUpdated
Inverter Relay Clicking On and Off

Short answer, inverter relay clicking: A repeated clicking sound from inside the inverter right after you turn it on, with the screen and lights flashing, has one listed cause in the manuals.

What the manuals say

In the Growatt SPF ES, Fronus Infineon and Inverex Aerox troubleshooting tables: “When it’s turned on, internal relay is switched on and off repeatedly” with the LCD display and LEDs flashing. Explanation: battery is disconnected. Fix: check whether battery wires are connected well.

What to check

  1. Switch the inverter off.
  2. Check that both battery cables are firmly attached at the inverter and at the battery.
  3. Look for a loose lug, corroded terminal or a cable that came off during cleaning.
  4. Check any battery breaker or isolator, if fitted, is switched on.

On the Growatt SPF ES, a disconnected battery can also show as warning 19 (battery disconnected) or fault 56 (battery connection open).

Safety: Inverters, batteries and solar panels carry dangerous voltages. Only do checks from outside the unit. For anything inside, contact an authorised service centre.

Related: free solar tools and the Error Code Finder.

Roman Urdu mein: Inverter on karte hi andar se relay baar baar "tik tik" kare aur screen jhapke to manual ke mutabiq battery jurri hui nahi. Battery ki taarein aur breaker check karein.

Frequently asked questions

Is the clicking dangerous?

It is the relay switching because the battery is not connected; switch off and check the battery wires.

Which Growatt codes relate to this?

Warning 19 (battery disconnected) and fault 56 (battery connection open).

Sources: troubleshooting and warning tables in the Growatt SPF 3500/5000 ES, Fronus Infineon 3.5/5.5KVA and Inverex Aerox 1.2 to 3.2KW user manuals. Copies: Growatt SPF ES manual Fronus Infineon manual Inverex Aerox manual (hosted by third parties, not by the brands).