Short answer, connect battery to inverter: Most battery problems in inverter manuals come down to the connection. Here are the checks that prevent them.
Before you start
- Match the battery bank voltage to the inverter (12V, 24V or 48V).
- Switch off the inverter and open the battery breaker.
- Work with insulated tools and remove rings and watches.
Polarity
Connect positive to positive and negative to negative. The Growatt SPF ES manual lists reversed polarity as a reason for the inverter not responding at all.
Tight, clean connections
Loose cables cause relay clicking and battery warnings. The manuals link repeated relay clicking at power-on to a disconnected battery.
Cable and breaker
Use the cable size and DC breaker given in your inverter manual for its battery current. Undersized cable heats up.
Settings
Set the battery type in the inverter (lead-acid or lithium). For lithium, enable BMS communication if both support it.
Safety: battery banks can deliver very high current. If unsure, ask a qualified technician.
Related: free solar tools and the Error Code Finder.
Roman Urdu mein: Battery lagane se pehle volt match karein, plus ko plus aur minus ko minus lagayein, taarein tight rakhein, manual ke mutabiq cable aur breaker lagayein aur inverter mein battery type set karein.
Frequently asked questions
What happens if I reverse the battery cables
The Growatt SPF ES manual lists reversed polarity as a cause of no response at power-on. Ask a technician to check.
Do I need to change settings for lithium
Yes, set the battery type and enable BMS communication if supported.
Sources: troubleshooting and warning tables in the Growatt SPF 3500/5000 ES, Fronus Infineon 3.5/5.5KVA and Inverex Aerox 1.2 to 3.2KW user manuals. Copies: Growatt SPF ES manual Fronus Infineon manual Inverex Aerox manual (hosted by third parties, not by the brands).