Growatt SPF 5000 ES Fault Codes Full List with Meanings
Growatt SPF 5000 ES fault codes and warning codes with meanings from the official manual, plus links to causes and step-by-step fixes. English and…
Growatt SPF 3500 and 5000 ES fault and warning codes from the official user manual.

Growatt SPF 5000 ES fault codes and warning codes with meanings from the official manual, plus links to causes and step-by-step fixes. English and…

Growatt SPF warning 19 means the battery is disconnected. Check battery cables, breaker and terminals as the official troubleshooting table advises. With FAQ.

Growatt SPF warning 04 means low battery, with one beep every second. What it means, why it happens and what to check, from the…

Growatt SPF fault 80 (CAN fault) and 81 (host loss) appear in parallel systems. Check the communication cables and Program 23, as the manual…

Growatt SPF fault 60 is a negative power fault. The SPF 3500 and 5000 ES manual asks you to check that AC output is…

Growatt SPF fault 56 means the battery connection is open: the battery is not connected well or the fuse is burnt. Check the connections…

Growatt SPF fault 55 appears in parallel systems when output voltage is unbalanced. Manual checks: Program 8, current sharing cables and neutral wiring.

Growatt SPF fault 52 means the internal bus voltage is too low. The SPF 3500 and 5000 ES manual says to return the unit…

Growatt SPF fault 51 means over current or surge. If the battery is connected well, the SPF 3500 and 5000 ES manual says send…

Growatt SPF fault 08, 09, 53 or 57 points to failed internal parts in the 3500 or 5000 ES. The manual says restart once,…

Growatt SPF fault 07 means overload: the inverter carried more than 110% load for too long. Reduce the load as the SPF 3500 and…

Growatt SPF fault 06 or 58 means output voltage is too high or too low, below 190Vac or above 260Vac. Manual steps: reduce load,…