Short answer: Growatt SPF Warning 04. Warning 04 on a Growatt SPF 3500/5000 ES means the battery voltage is low. The inverter warns you before it shuts down to protect the battery. First step: reduce the load to slow down the discharge.
04
What this warning means
The manual's warning table lists 04 as low battery, beeping once every second.
If the battery keeps discharging, the inverter will stop supplying the load. At startup, the manual links shutdown after 3 seconds to battery voltage below 1.91V per cell.
Possible causes (from the manual)
- Battery is discharged by the load
- Battery has aged and holds less charge
- Loose battery cables can make the voltage drop under load
How to fix it, step by step
- Reduce the load to slow down the discharge.
- Let the battery charge from solar or WAPDA.
- Check that battery cables are tight and terminals clean.
- If it appears soon after a full charge, have the battery tested.
Safety: If the code returns after these checks, contact the authorised service centre. Do not open the inverter yourself.
Roman Urdu mein: Growatt warning 04 ka matlab battery kam hai, har second ek beep. Load kam karein, battery charge hone dein aur taarein check karein. Poori charge ke baad bhi jaldi aaye to battery check karwayein.
Frequently asked questions
Will the inverter shut down after warning 04?
If the battery keeps discharging it will stop supplying power to protect the battery.
Can old batteries cause warning 04?
Yes, an aged battery holds less charge and reaches low voltage sooner.
Source: Growatt SPF 3500 ES / SPF 5000 ES Off-Grid Solar Inverter User Manual (Fault Reference Code, Warning Indicator, Trouble Shooting). Open a copy of this manual (hosted by manuals.plus, not by the brand). Codes and settings can differ between firmware versions, so always compare with the manual that came with your unit.
More Growatt SPF 3500/5000 ES codes
- Full Growatt SPF 3500/5000 ES code list
- Growatt SPF Fault 01
- Growatt SPF Fault 02
- Growatt SPF Fault 03
- Growatt SPF Fault 05
- Growatt SPF Fault 06 and 58
- Growatt SPF Fault 07
Have a different code? Use the Error Code Finder.