Inverter Error Codes
Inverter fault and warning codes with meanings, causes and step by step fixes taken from the official manuals, in English and Roman Urdu.
Growatt error codes →
Inverex error codes →

Inverex Nitrox F35 No AC Grid
Inverex Nitrox F35 means No AC Grid on the Nitrox on-grid inverter. The manual troubleshooting table lists grid failure as the cause. What to…

Inverex Aerox Fault 08 and 09 Internal Failure
Inverex Aerox fault 08 (bus voltage too high) or 09 (bus soft start failed) means internal parts failed. The manual says return it to…

Inverex Aerox Fault 07 Overload
Inverex Aerox fault 07 overload: above 105% for too long, or derating from high PV voltage. Reduce load or PV modules in series. English…

Inverex Aerox Fault 06 Output Voltage Abnormal
Inverex Aerox fault 06: output abnormal, inverter voltage below 190Vac or above 260Vac. Reduce the load, then repair centre. In English and Roman Urdu.

Inverex Aerox Fault 05 Output Short or Over Heat
Inverex Aerox fault 05: output short circuit, or internal converter above 120°C. Check wiring, remove abnormal load, check airflow. English and Roman Urdu.

Inverex Aerox Fault 03 Battery Voltage Too High
Inverex Aerox fault 03 means the battery is over-charged. Check battery specification and quantity; then return to the repair centre. English and Roman Urdu.

Inverex Aerox Fault 02 Over Temperature
Inverex Aerox fault 02 is over temperature: inverter parts over 100°C. Check airflow and room temperature, as the manual advises. English and Roman Urdu.

Fronus Infineon Fault 59 PV Voltage Over Limit
Fronus Infineon fault 59 means PV (solar panel) voltage is over the limit. The manual's fix: reduce the number of PV modules in series.…

Fronus Infineon Fault 51 Over Current or Surge
Fronus Infineon fault 51 means over current or surge. Restart the unit; if the error happens again, return it to the repair centre. English…

Fronus Infineon Fault 08 09 53 57 Internal Failure
Fronus Infineon fault 08, 09, 53 or 57 means internal parts failed. The 3.5KVA and 5.5KVA manual says to return the unit to the…

Fronus Infineon Fault 07 Overload
Fronus Infineon fault 07 overload: above 110% for too long. The manual also links it to PV voltage above spec causing derating. English and…

Fronus Infineon Fault 06 and 58 Output Voltage Abnormal
Fronus Infineon fault 06/58: output abnormal, inverter voltage below 190Vac or higher than 260Vac. Reduce load, then repair centre. English and Roman Urdu.