Fronus Infineon Fault 05 Output Short Circuit
Fronus Infineon fault 05: output short circuited, or converter over temperature. Check wiring and remove abnormal load. Explained in English and Roman Urdu.

Fronus Infineon Fault 03 Battery Voltage Too High
Fronus Infineon fault 03 means the battery is over-charged and its voltage too high. Check battery specification and quantity. English and Roman Urdu.

Fronus Infineon Fault 02 Over Temperature
Fronus Infineon fault 02: over temperature. Converter parts over 120°C or inverter parts over 100°C. Check airflow and room heat. English and Roman Urdu.

Fronus Infineon Fault 01 Fan Locked
Fronus Infineon fault 01 on the 3.5KVA or 5.5KVA means the fan is locked. The manual fix is to replace the fan. Safe checks…

Growatt SPF Fault 80 and 81 Parallel Communication
Growatt SPF fault 80 (CAN fault) and 81 (host loss) appear in parallel systems. Check the communication cables and Program 23, as the manual…

Growatt SPF Fault 60 Negative Power
Growatt SPF fault 60 is a negative power fault. The SPF 3500 and 5000 ES manual asks you to check that AC output is…

Growatt SPF Fault 56 Battery Connection Open
Growatt SPF fault 56 means the battery connection is open: the battery is not connected well or the fuse is burnt. Check the connections…

Growatt SPF Fault 55 Output Voltage Unbalanced
Growatt SPF fault 55 appears in parallel systems when output voltage is unbalanced. Manual checks: Program 8, current sharing cables and neutral wiring.

Growatt SPF Fault 52 Bus Voltage Too Low
Growatt SPF fault 52 means the internal bus voltage is too low. The SPF 3500 and 5000 ES manual says to return the unit…

Growatt SPF Fault 51 Over Current or Surge
Growatt SPF fault 51 means over current or surge. If the battery is connected well, the SPF 3500 and 5000 ES manual says send…

Growatt SPF Fault 08 09 53 57 Internal Failure
Growatt SPF fault 08, 09, 53 or 57 points to failed internal parts in the 3500 or 5000 ES. The manual says restart once,…

Growatt SPF Fault 07 Overload
Growatt SPF fault 07 means overload: the inverter carried more than 110% load for too long. Reduce the load as the SPF 3500 and…