Inverex Aerox Fault 07 Overload

InverexUpdated
Inverex Aerox Fault 07 Overload

Short answer: Inverex Aerox Fault 07. Fault 07 on an Inverex Aerox is an overload. The Aerox manual says the inverter is overloaded at 105% and the time is up. First step: reduce the connected load by switching off some equipment.

07W07

What this fault means

Note that the Aerox manual uses 105%, while some other inverters' manuals use 110%. Always go by your own model's manual.

The manual also explains that PV input voltage above specification derates output power, so a normal load can become an overload during sunshine.

Possible causes (from the manual)

  • Overload error: the inverter is overloaded 105% and the time is up
  • High PV input voltage derates output; load above the derated output causes overload

How to fix it, step by step

  1. Reduce the connected load by switching off some equipment.
  2. Reduce the number of PV modules in series or the connected load.

Warning 07 on the same inverter

The warning table lists 07 as overload, beeping once every 0.5 second.

If the overload continues, the inverter stops with fault 07. The Aerox manual describes fault 07 as overload error, inverter overloaded 105% and time is up.

What to do when the warning shows

  1. Switch off heavy appliances immediately.
  2. Start motor loads one by one.
  3. Add up your loads with the Solar Load Calculator.
  4. If the warning shows with a small load, contact the service centre.

Safety: If the code returns after these checks, contact the authorised service centre. Do not open the inverter yourself.

Roman Urdu mein: Inverex Aerox fault 07 overload hai (105%). Load kam karein. Din mein aaye to panels ka voltage zyada ho sakta hai – installer se series panels kam karwayein.

Frequently asked questions

Why 105% and not 110%?

That is the figure in the Aerox manual. Different models use different limits.

Which appliances use most power?

Use our Solar Load Calculator to add up your appliance wattage.

At what load does fault 07 happen?

The Aerox manual says the inverter is overloaded 105% and the time is up.

Source: Inverex AEROX 1.2KW-3.2KW MPPT Solar Inverter User Manual, Version 1.0 (Fault Reference Code, Warning Indicator, Trouble Shooting). Open a copy of this manual (hosted by ManualsLib, not by the brand). Codes and settings can differ between firmware versions, so always compare with the manual that came with your unit.