Inverex Nitrox Error Codes F01 to F64 Full List

InverexUpdated
Inverex Nitrox Error Codes F01 to F64 Full List

Short answer: Inverex Nitrox error codes: this page lists every fault code in the Inverex Nitrox 12-25KW manual with its meaning. Click a code for causes and fixes.

This is the complete F01–F64 error code list from the Inverex Nitrox 12KW–25KW three-phase on-grid inverter manual.

Error codes

CodeMeaning (as in the manual)Details
F01DC input polarity reverse fault–
F02DC insulation impedance permanent fault–
F03DC leakage current fault–
F04Ground fault GFDI (battery and grounding)–
F05Read the memory error–
F06Write the memory error–
F07GFDI blown fuse–
F08GFDI grounding touch failure–
F09IGBT damaged by excessive drop voltage–
F10Auxiliary switch power supply failure–
F11AC main contactor errors–
F12AC auxiliary contactor errors–
F13Reserved–
F14DC firmware over current–
F15AC firmware over currentCauses & fix
F16GFCI (RCD) AC leakage current fault–
F17Three phase current, over-current fault–
F18AC over current fault of hardwareCauses & fix
F19All hardware failure synthesis–
F20DC over current fault of the hardware–
F21DC leakage flow fault–
F22Crash stop (if there is a stop button)–
F23AC leakage current is transient over currentCauses & fix
F24DC insulation impedance failureCauses & fix
F25DC reverse irrigation failure–
F26The DC busbar is unbalancedCauses & fix
F27DC end insulation error–
F28Inverter 1 DC high fault–
F29AC load switch failure–
F30AC main contactor failure–
F31AC secondary contactor failure–
F32Inverter 2 DC high fault–
F33AC over current–
F34AC current over load–
F35No AC gridCauses & fix
F36AC grid phase error–
F37AC three-phase voltage imbalance failure–
F38AC three-phase current imbalance failure–
F39AC over current–
F40DC over current–
F41AC line W,U over voltageCauses & fix
F42AC line W,U low voltageCauses & fix
F43AC line V,W over voltageCauses & fix
F44AC line V,W low voltageCauses & fix
F45AC line U,V over voltageCauses & fix
F46AC line U,V low voltageCauses & fix
F47AC over frequencyCauses & fix
F48AC lower frequencyCauses & fix
F49U phase grid current DC over current–
F50V phase grid current DC over current–
F51W phase grid current DC over current–
F52AC inductor A, phase current DC current high–
F53AC inductor B, phase current DC current high–
F54AC inductor C, phase current DC current high–
F55DC busbar voltage is too highCauses & fix
F56DC busbar voltage is too lowCauses & fix
F57AC reverse irrigation–
F58AC grid U over current–
F59AC grid V over current–
F60AC grid W over current–
F61Reactor A phase over current–
F62Reactor B phase over current–
F63Reactor C phase over current–
F64IGBT heat sink high temperature–

What the manual asks you to do

For error codes, the Nitrox manual asks you to contact your distributor and provide: the inverter serial number, the dealer or distributor, the installation date, a description of the problem (including the LCD error code and LED status) and your contact details.

Code F13 is marked as reserved in the manual.

Safety: If the code returns after these checks, contact the authorised service centre. Do not open the inverter yourself.

Roman Urdu mein: Inverex Nitrox ke F01 se F64 tak error codes manual se. Zyada tar codes ke liye manual distributor se rabta karne ko kehta hai.

Frequently asked questions

Where do these Inverex codes come from?

From the official manual: Inverex NITROX-12KW / 15KW / 20KW / 25KW (3Ph-5G) PV Solar On-Grid Inverter User Manual, section 10 (Error code, Troubleshooting).

What if my code is not in this list?

Your unit may be a different model or firmware. Check the manual that came with your inverter or contact the service centre.

Source: Inverex NITROX-12KW / 15KW / 20KW / 25KW (3Ph-5G) PV Solar On-Grid Inverter User Manual, section 10 (Error code, Troubleshooting). Open a copy of this manual (hosted by manuals.online, not by the brand). Codes and settings can differ between firmware versions, so always compare with the manual that came with your unit.